isibhengezo_sekhasi

I-MANSON MM7 Centrifuge ye-8ml - 15ml PRP Tubes

I-MANSON MM7 Centrifuge ye-8ml - 15ml PRP Tubes

incazelo emfushane:

Inombolo Model: MM7

Isivinini esikhulu: 4000 r / min

Ubukhulu be-RCF: 1980 * g

Bonisa: I-LED / LCD

Amandla: AC 220V 50 Hz

Umsindo: <65 dB (A)

Amandla: 8 x15 ml Swing Rotor


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

I-MM7 Centrifuge (2)

I-PRP Centrifuge isebenzisa isilungiselelo se-centrifugal ukuze ihlukanise, ihlanzeke futhi ifinyeze
i-granule.Ingasetshenziswa kabanzi emkhakheni wezokwelapha, i-biochemistry, ubunjiniyela bezakhi zofuzo kanye ne-radioimmunology.Kuyimishini ekahle yesikhungo socwaningo lwesayensi nesibhedlela.

I-MANSON MM7 Low Speed ​​PRP Centrifuge iklanywe ngochwepheshe bethu bezobuchwepheshe.Ukuze sikhulule ngokugcwele umsebenzi we-PRP, senze ucwaningo oluningi ku-Rotor, Isivinini sokugijima, i-RCF kanye ne-Time of Acc/Dcc.Uma kusetshenzwa ngamakhithi e-MANSON PRP, ingakhipha i-PRP ngempumelelo futhi inciphise isikhathi, ithuthukise ukusebenza kahle komsebenzi futhi yenze yonke inqubo yokwelapha.

Izici ze-MM7 Centrifuge

I-centrifuge encane nesebenzayo yamavolumu amancane amasampula.
1. Inefreyimu engenabala, eqinile, ehlala isikhathi eside futhi ephephile;Ngesembozo sengilazi ephilayo esemfashinini, nesisindo esincane.
2. Ukulawulwa kwe-Microprocessor, Kulawulwa yi-DC brushless frequency conversion electromotor enomsindo ophansi nokudlidliza.
3. Isibonisi se-LCD, iphaneli yokuthinta nesibonisi sedijithali, isikhombikubona esinobuntu, ukusebenza kalula.
4. Ngokuvikeleka kokungalingani kanye nekhava yomnyango, enomsebenzi othusayo.Iphephile futhi inokwethenjelwa.
5. Idizayinelwe ngokukhethekile ikhithi ye-Krean PRP, ithuthukise izinga lokusinda le-PRP(Platelet rich plasma).
6. Yiba ne-programe ekhethekile yesikhathi sokubhuleka, ingakhipha isikhathi se-PRP 2 kune-centrifuge evamile.
7. Yonke le modeli inezinzuzo zayo, uma unombuzo pls ukhululeke ukusazisa.
8. Isebenza ngaphandle kokungcoliswa kothuli lwekhabhoni, olungahlangabezana nezidingo zelabhu.
9. Yamukela isihlukanisi esikhethekile sokushaqeka ukuze uthole umphumela omuhle wokudambisa ukudlidliza, nomsebenzi webhalansi ezenzakalelayo.
10. Amadivayisi okuphepha anombukiso wephutha ohlanganisa isivinini esingaphezulu, ukuvala isivalo, ukungalingani, njll.
11. Ukubuka imbobo esivalweni, ukhiye wokuhlola we-RCF.

I-MM7 Centrifuge (3)
Isivinini esikhulu 4000 r / iminithi
Ubukhulu be-RCF 1980*g
I-Max Sapacity I-Angle Rotor, 15ml * 8 izinkomishi
Ukunemba Kwesivinini ± 50 r / iminithi
Amashubhu atholakalayo 8 – 15 ml PRP Tubes
Iwaranti iminyaka engu-2
Ibanga Lesikhathi 1 iminithi~99 min
Ukunikezwa kwamandla kagesi ~220V 50 / 60Hz 2A
Umsindo < 65 dB (A)
Ubukhulu 265mm*305mm*205mm (W*L*H)
Isisindo NW: 8.5KG
Izidingo Zemvelo Izinga lokushisa: 10℃~35℃, Ukuswakama okuhlobene: ≤ 85%

I-MM7 low speed centrifuge yakhiwa umshini oyinhloko kanye nezinsiza.Umshini omkhulu wakhiwe ngekesi,uhlelo lwedrayivu,uhlelo lokulawula kanye nengxenye yesibonisi esikhulu.I-rotor neshubhu elimaphakathi kungokwesekeli.

Isetshenziswa kanjani?

I-MM7 PRP Centrifuge ye-Classic PRP Kit yethu (3500rpm, 8minutes)

I-1) Ukuhoxisa Igazi futhi Ulungiselele i-PRP
Gcwalisa amashubhu e-PRP ngegazi lesiguli.Ngokushesha ngemva kokuthatha isampula, vula ishubhu libe ngu-180 libheke phansi, unyakazise futhi uxube izikhathi ezingu-6-8.
2) I-Centrifugation
Igazi libe selifakwa ku-centrifuge imizuzu engu-8 ku-1500g.Beka amashubhu ngokumelene nomunye ukuze ulinganise.Igazi lizohlukaniswa.I-PRP(Platelet-Rich Plasma) izoba phezulu namangqamuzana egazi abomvu namangqamuzana amhlophe egazi phansi, iplasma empofu yeplatelet ilahlwe.Amaplatelet agxilile aqoqwa abe Isirinji Eyinyumba.
3) I-Aspirate PRP
Ngemva nje kwe-Centrifugation, ukufisa i-PRP.Qiniseka ukuthi awuwakhi Amaseli Egazi Abomvu.
Iqoqa yonke i-plasma ecebile ye-platelet futhi ilungele iziguli.

I-MM7 Centrifuge (4)

Iphrofayela Yenkampani

I-MM7 Centrifuge (8)

Izitifiketi

I-MM7 Centrifuge (6)

Ukupakisha Nokulethwa

I-MM7 Centrifuge (9)

  • Okwedlule: